FAST Field Screening Capabilities

These are the technical/analytical capabilities of the equipment in the FAST Vehicle.

FAST Field Screening Capabilities

ParameterEquipmentDetection Limits/Ranges
Total Volatile Organic Compounds (VOCs) in airPhotoionization Detectors (PIDs)1 ppmV (AreaRAE and Sirius units) and 10 - 50 ppbV (PID Analyzer)
Individual VOCs and Hydrocarbons (all media)
 
GC/ELCD/PID
GC/FID
 
5 - 50 ppbV in air or soil gas; 1-5 ug/L in water; mg/kg range in soil/ sediments
Explosive Gases (air)
 
Various LEL meters & AreaRAEs1-100% of Lower Explosive Limit (LEL)
Explosive Gases (air)V-RAE1-100% of explosive gases
Ammonia (air)V-RAE #21 ppmV
Ammonia (air)Various PIDs/AreaRAEs10 ppmV
 
Ammonia (water)Hach Kit0.4 - 50 mg/L
Asbestos (solids and air)Phase Contrast Microscope (PCM)0.01 fibers/cc in air samples
Asbestos (solids and air)Polarized Light Microscope (PLM)5 - 10% in bulk samples
Carbon Monoxide (air)M40 Meters1 ppmV
Coliform/E. coli (water)Colilert System1 organism/100 mL
Chlorine (air)V-RAE #1; AreaRAEs0.1 ppmV
Chlorine (water)Hach Kit0.02 - 2 mg/L
Chromium +6 (water)Hach Kit0.01 - 0.7 mg/L
Copper (water)Hach Kit0.04 - 5 mg/L
Dust (air)Thermo MIE pDR-15001-400,000 ug/m3
Enterococci (water)Enterolert System1 organism/100 mL
Hydrogen Chloride (air)PID Analyzer1 ppmV
Hydrocyanic acid (air)Draeger Tubes10 ppmV
Hydrogen Cyanide (air)V-RAE #21 ppmV
Hydrogen Fluoride (air)Draeger Tubes0.5 ppmV
Hydrogen Sulfide (air)V-RAE #1; M40 meters; AreaRAEs1 ppmV
Mercury Vapor (air)Lumex Meter2 ng/m3
Mercury Vapor (air)Jerome Meter3000 ng/m3
Metals (soil)Niton XRF meter100 - 900 mg/kg, depending on metal
Methane (soil gas/air)GC/FID1 ppmV
Nitrates (water)Hach Kit0.2 - 30 mg/L
Nitric Acid (air)Draeger Tubes1 ppmV
Nitrogen, Total (water)Hach Kit0.5 - 25 mg/L
Nitrous gases (air)Draeger Tubes5 ppmV (as NO2)
Orthophosphate (water)Hach Kit0.06 - 5 mg/L (as PO4)
Oxygen (air)M-40 meters0.1 -30%
Phosgene (air)Draeger Tubes0.5 ppmV
Phosphine (air)Draeger Tubes0.3 ppmV
Phosphorus, total (water)Hach Kit0.06 - 3.5 mg/L (as PO4)
Radiation, gammaCanberra UltraRadiac1 uR/hr
Styrene (air)Draeger Tubes10 ppmV
Sulfur dioxide (air)Draeger Tubes10 ppmV
Unknowns (liquids/solids)First DefenderPercent ranges

Help Us Improve Mass.gov  with your feedback

Please do not include personal or contact information.
Feedback