- This page, Board of Elevator Regulations Meeting - 11.3.26, is offered by
- Division of Occupational Licensure
- Office of Public Safety and Inspections
- Board of Elevator Regulations
Public Meeting Notice Board of Elevator Regulations Meeting - 11.3.26
Overview
This will be a hybrid meeting at One Federal Street, Boston, MA, 6th Floor or via the teams link in the agenda.
You will need
Microsoft Teams meeting link and dial-in number
Join: Microsoft Teams Meeting Link
Meeting ID: 289 252 670 290 277 7
Passcode: dm93Ks2D
Dial in by phone
+1 857-327-9245,,291527160# United States, Boston
Phone conference ID: 291 527 160#
In accordance with the provisions of G. L. c. 30A, §20, and Chapter 2 of the Acts of 2025, notice is hereby given that a hybrid meeting of the Board of Elevator Regulations will be held on Tuesday, November 3, 2026, at 1:00 p.m.
Agenda
It is anticipated that the topics shown below will be discussed at the aforementioned meeting:
- Roll Call.
VAR26-0051
50 Western Avenue Boston
State ID: 1-P-27610
Code Reference: 524 CMR 35.00 in reference to ASME A17.1-2013 Section 2.2.2.5
Petitioner: Emma Molloy
The petitioner is seeking a variance from 524 CMR 35.00 in reference to ASME A17.1-2013 Section 2.2.2. The project is requesting to install a sump pump located outside of the elevator pit. The building was constructed using post-tenson concrete, and the elevator pit is depressed into the foundation mat slab. Cutting into this area to add a sump pump pit is not advised by the Structural and Plumbing Engineers of Record.
VAR26-0060
0 Broadway Station Boston
New Install
Code Reference: ASME A17.1 - 6.1.3.6.4
Petitioner: Jay Barfield
The petitioner is seeking a variance of ASME A17.1 - 6.1.3.6.4 for a new MBTA Escalator at Broadway Station as the headhouse security gate impedes on the escalator's Safety Zone when the station is closed.
VAR26-0061 & VAR26-0062
53 Sturbridge Road Charlton
State IDs: 54-V-25117 & 54-V-25118
Code Reference: 524 CMR 32.01
Petitioner: Christine Parnell
The petitioner is seeking a variance of 524 CMR 32.01, in which they are providing additional safety measures for the VRC’s hoistway ledge, in which they were recently cited in inspection(s).
- VAR26-0066
111 Foster Street Peabody
State ID: 229-P-57
Code Reference: A17.1.3.19.4.7
Petitioner: Christen Parsons
The petitioner is seeking a variance of A17.1.3.19.4.7 to allow the victaulic fitting and threaded adapter to be used.
- Matters not reasonably anticipated 48 hours in advance of meeting.
- Old business (The Board may or may not discuss):
- VAR26-0042 & VAR26-0043
25 Northern Avenue Boston
State ID: 1-E-16035 & 1-E-16036
Code Reference: ASME A17.1-2013 Section 6.1.3.6.4 - Safety Zone
Petitioner: Brennan Clarke
The petitioner was before the board on July 7, 2026, and the board voted to place the item on a 120-day hold, which provided a deadline of November 4, 2026, for the applicant to investigate additional options for code compliance or provide documentation showing the scope of hardship.
The petitioner is seeking a variance from ASME A17.1-2013 Section 6.1.3.6.4 - Safety Zone in which they are proposing a solution for the deficiency.
VAR26-0056
Product Variance - Outlook Outdoor Elevator
Code Reference: ASME A17.1 (2025) Section 5.3.1.1.2 (b)
Petitioner: Jason Ford
The petitioner is seeking a Product Variance for the Outlook Outdoor Elevator, which is compliant except for ASME A17.1 (2025) Section 5.3.1.1.2 (b). As this is a completely shaftless elevator, there is no hatch cover closing an opening through the floor. Instead, it has a top obstruction safety pan covering the entire top of the cab. The top safety pan will shut the unit off in the up direction when 20 lbs. or more is placed on the top.
- VAR26-0055
7 Blanchard Road Cambridge
New Install
Code Reference:524 CMR Chapter 26 Section 26.04 - Classification
Petitioner: Duncan MacArthur
The petitioner is seeking a variance of 524 CMR Chapter 26 Section 26.04, to formally request a determination of jurisdiction regarding a piece of equipment currently being installed. It is their position that this device does not fall under the purview of 524 CMR Section 26: Certain Elevator Equipment Used as Motor Vehicle Parking Devices.
If you need reasonable accommodations to participate in the meeting, please reach out to Cheryl Yebba at 617-701-8711. While the Board will do its best to accommodate you, certain accommodations may not be available if requested immediately before the meeting.
Please be advised that recording meetings without prior permission from the board chair, by any means, including the use of any A.I. applications, is strictly prohibited.