Public Meeting Notice Board of State Examiners of Plumbers and Gas Fitters Code Subcommittee Meeting - 9.16.26
Overview
This is a remote meeting. You can participate from your computer, laptop, or smartphone. See Meeting Agenda for details.
You will need
Microsoft Teams meeting link
Join: Join Meeting
Meeting ID: 264 632 514 321 205
Passcode: ZV33V9jm
Dial in by phone
+1 857-327-9245,,809742243# United States, Boston
Phone conference ID: 809 742 243#
In accordance with the provisions of G.L. c. 30A § 20, notice is hereby given that the Board of State Examiners of Plumbers and Gas Fitters Plumbing Board Subcommittee will be convening their monthly meeting.
Meeting Minutes
In accordance with the provisions of G.L. c. 30A § 20, the Board of State Examiners of Plumbers and Gas Fitters convened plumbing subcommittee meeting:
Microsoft Teams Meeting Wednesday September 16, 2026, at 1:00 pm
The topics shown below were discussed at the aforementioned meeting: 1:00 pm the Chair, Joseph McNamee called the open meeting to order.
Informational note: All votes were taken by roll call. Where each member voted in favor, the vote will be reported as unanimous.
Board members present:
- Mr. Joseph McNamee, Chairman, Master Gas Fitter
- Mr. John Cruz, Member, LP Installer
- Ms. Sarah Badway, Public Member
- Mr. Dan Kilburn, Member, DOL Designee
- Ms. Kimberly Garside, Member, Master Plumber
Board members absent:
- Mr. Harold Knight, Vice-Chairman, Journeyman Plumber
- Mr. Bahig A. Kaldas, P.E., Member, plumbing Engineer
- Mr. Wayne Thomas, Member, Journeyman Gas Fitter
- Ms. Katharine Dagle, Department of Public Health
DOL Staff present:
- Mr. Michael Auerbach, Executive Director
- Mr. Michael Guida, Board Code and Technical Coordinator
- Mr. Charles Kilb, Board Legal Counsel
- Mr. James O’Reilly, State Plumbing and Gas Inspector
- Mr. Scott Padden, State Plumbing and Gas Inspector
- 1:14 p.m. Open Meeting Called to Order
- Note Meeting Recording
- Roll Call by Chair for Quorum
Approval of previous Meeting Minutes
- Approval of Meeting Minutes
- August 19, 2026, Subcommittee Meeting
Tabled
- Legal / Board Counsel Report – Charles Kilb
None
Discussion
Reviewed proposed changes for the following sections
- 248 CMR 10.01, Scope and Jurisdiction
No changes made at this meeting
- 248 CMR 10.02, Basic Principles
Members and staff reviewed the accessibility requirements for common laundry facilities, including whether access should be provided directly through the main building. The group also discussed the potential use of an outbuilding. Staff presented the following option for possible code language created by CK.
248 CMR 10.02 Basic Principle 6(a)5biv: A building containing multiple dwellings (“primary building”) shall be exempt from this section so long as required washing machine connections are provided in an accessory building or structure which is located on the same property as the primary building so long as said accessory building or structure is accessible to the occupants of the primary building. Said accessory building or structure may only be utilized for this purpose if permitted by the local zoning authority.
Vote: JC to approve JK second
Discussion: Members asked about this affecting ADU’s. It was clarified that this would be a stand alone building separate from the residence of a multi-unit building. The members also discussed the use of the building other than laundry. CK clarified the use of the building to be a stand-alone laundry facility.
Result: Motion carried unanimously
- 248 CMR 10.03, Definitions
Staff presented a definition of Interstitial that is used in section 10.09 Interceptors, Separators, and Holding Tanks used to describe a double walled holding tank.
Interstitial: A device installed within the space between the inner and outer walls of a double‑wall tank or piping system, designed to detect the presence of liquid indicating a leak.
Staff asked the members to return to this section when this term is covered in 248 CMR 10.09
At 1:26 pm, quorum was no longer present; therefore, the meeting recessed until a quorum could be reestablished.
At 1:33 pm, a quorum was reestablished, and the meeting resumed.
- 248 CMR 10.04, Testing and Safety
No changes made at this meeting
248 CMR 10.05, General Regulations
Staff presented a proposal to establish minimum and maximum pipe grades consistent with the requirements of 248 CMR 10.15, Table 2.
Discussion: Members discussed potential applications of the proposed pipe grade and agreed that establishing a standard grade was necessary. Staff will evaluate potential revisions to 248 CMR 10.15, Table 2, as the current table does not address DFU values for all pipe diameters.
Vote: JC to approve JK second
Results: motion carried unanimously
- 248 CMR 10.06, Materials
Staff presented adding limited use of PVC and ABS for fixture drains commercially to 248 CMR 10.06(1)(g)4.
Vote: JC to approve JP second
Discussion: MG and JO explained that the item was being presented for discussion to gauge the committee's interest and determine whether further action was warranted. Some members showed opposition to exploring the expanded use of PVC. KG expressed concerns over possible fumes and may add additional problems to occupied area.
Results: Following discussion, JC withdrew the motion. No vote was taken
- 248 CMR 10.07, Joints and Connections
No changes made at this meeting
- 248 CMR 10.08, Traps and Cleanouts
No changes made at this meeting
- 248 CMR 10.09, Interceptors, Separators and Holding Tanks
No changes made at this meeting
- 248 CMR 10.10 (14), Plumbing Fixtures
No changes made at this meeting
- 248 CMR 10.11, Hangers and Support
No changes made at this meeting
- 248 CMR 10.12, Indirect Waste Piping
No changes made at this meeting
248 CMR 10.13, Piping and Treatment of Special Waste
Not covered at this meeting
- 248 CMR 10.14, Water Supply and Water Distribution System
Staff presented adding a tempering valve to 248 CMR 10.14 (6) as a requirement for all water heaters.
Vote: JC to approve JK second
Discussion: Members discussed the potential cost implications of these valves and concerns regarding their reliability in areas with hard water. Members noted that gas control valves on gas-fired water heaters have been known to fail. The Committee also discussed that the use of a tempering valve could provide an additional level of protection against scalding while helping to mitigate the risk of bacterial growth. The Committee directed staff to research the matter further, including any restrictions on the installation of tempering valves and the feasibility of limiting such requirements to commercial installations.
Result: Motion carried unanimously; JP was not part of the vote.
At 2:39 pm, quorum was no longer present; therefore, no further official business was conducted
- 248 CMR 10.15, Sanitary Drainage System
Not covered at this meeting
Adjournment
The Chair noted that quorum was no longer present and declared the meeting adjourned.
2:42 p.m.
Items relied upon during the open meeting
- Agenda
- Draft Topics
Note: If you need reasonable accommodation to participate in the meeting, please reach out to Cheryl Yebba at 617- 701-8711. The Agency will make best efforts to accommodate requests received in a timely manner.
Agenda
- 1:00 p.m. Open Meeting Called to Order
- Note Meeting Recording
- Roll Call by Chair for Quorum
| Members | Appointment |
|---|---|
| Mr. JosephMcNamee | Chairman, MasterGas Fitter |
| Mr. HaroldKnight | Vice-Chairman Journeyman Plumber |
| Mr. John Cruz | Member, LP Installer |
| Mr. Bahig A. Kaldas,P. E. | Member, Plumbing Engineer |
| Mr. WayneThomas | Member Journeyman Gasfitter |
| Ms. Katharine Dagle | Member, Dept.of Public Health |
| Mrs. Kimberly Garside | Member, Master Plumber |
| Mr. Joseph Peluso | Participant, Master Plumber |
| Mr. James Kennedy | Local Inspector, Participant |
| STAFF | Position |
| Mr. CharlesKilb | Board LegalCounsel |
| Mr. Michael Auerbach | Executive Director |
| Mr. Michael Guida | State Board Code and Technical Coordinator |
| Ms. Caitlyn Berry | Board Staff |
| Ms. Carrie Matheson | Board Staff |
| Mr. Scott Padden | State Plumbing & Gas Inspector |
| Mr. James O’Reilly | State Plumbing & Gas Inspector |
- Approval of Meeting Minutes
- August 19, 2026 Regular Meeting
- Legal / Board Counsel Report – Charles Kilb
- Discussion
- Reviewed proposed changes for the following sections
- 248 CMR 10.01, Scope and Jurisdiction
- 248 CMR 10.02, Basic Principles
- 248 CMR 10.03, Definitions
- 248 CMR 10.04, Testing and Safety
- 248 CMR 10.05, General Regulations
- 248 CMR 10.06, Materials
- 248 CMR 10.07, Joints and Connections
- 248 CMR 10.08, Traps and Cleanouts
- 248 CMR 10.09, Interceptors, Separators and Holding Tanks
- 248 CMR 10.10, Plumbing Fixtures
- 248 CMR 10.11, Hangers and Supports
- 248 CMR 10.12, Indirect Waste Piping
- 248 CMR 10.13, Piping and Treatment of Special Waste
- 248 CMR 10.14, Water Supply and Water Distribution System
- 248 CMR 10.15, Sanitary Drainage System
- 248 CMR 10.16 Vents and Venting