Overview

In accordance with Massachusetts General Laws Chapter 30A, Section 20, notice is hereby given that a meeting of the 527 CMR 12 Massachusetts Electrical Code Interpretation Committee is scheduled for Tuesday, December 17, 2024 at 1:00 p.m. via Microsoft Teams Meeting.

Agenda

Date:             December 17, 2024

Time:             1:00 p.m.

Location:      Microsoft Teams Meeting

Please be advised that recording meetings, by any means, including the use of any A.I. applications, without prior permission is strictly prohibited.

Microsoft Teams Meeting

Join on your computer, mobile app or room device

Click here to join the meeting

Meeting ID: 228 177 731 347 
Passcode: cWCe5U

Download TeamsJoin on the web

Or call in (audio only)

+1 857-327-9245,,160763968#   United States, Boston

Phone Conference ID: 160 763 968#

Find a local numberReset PIN

  1. Call to Order
  2. Introductions
  3. Agenda items:
    1. Review Meeting Minutes from November 19, 2024.
    2. Requests for interpretation:
      1. 527 CMR 12.00, 230.85 & 338 received from Bill Clinton, on November 15, 2024.

Question #1: On an existing dwelling when installing a listed switch or circuit breaker separate from a utility meter and marked “suitable for use as service equipment” and the MBJ is removed is this enclosure permitted to be labeled Emergency Disconnect – Not Service equipment as per 230.85(B)(3) 230.85(E)(1)(3) and 230.85(E)(2).

Question #2: Is SEU (3 wire) cable permitted to be installed from the listed switch or circuit breaker marked Emergency Disconnect – Not service equipment enclosure to listed and labeled Service equipment – Such as a Main Breaker load center – as permitted in 338.10(A)

Question #3: The listed SEU (3 wire) cable assembly is installed to provide power as a ‘service entrance’ conductor from a listed switch or circuit breaker (230.85) & 338.10(A) to a Main Breaker load center as the service panel, does the grounded conductor (neutral) need to be insulated?

  1. Items not anticipated    
  2. Adjournment

Contact

Address

1 State Road, Stow, MA 01775

Fax

978-567-3199

Address

Department of Fire Services
1 State Rd., P.O. Box 1025, Stow, MA 01775

Fax

978-567-3199

Help Us Improve Mass.gov  with your feedback

Please do not include personal or contact information.
Feedback